Logout
Reverse
Introduction
When operating locally, using throttle or pedal inputs, it is possible to command the motor to go in reverse via a switch or a message over the network. This page describes the available inputs and how to configure the parameters accordingly.
Reverse inputs
Firmware 6.018 and older
Cruise/Digital input 1 is the only input option.
Typically a single throw switch is used between Cruise and Ground.
Firmware 6.019 and newer
Available input sources include Cruise/Digital input 1, PFS/Digital input 2 or network.
For Cruise or PFS, typically a single throw switch is used between your selected input and Ground.
For network, a command must be sent to Remote Digital Commands bit 15 Enable reverse.
Reverse setup
Firmware 6.018 and older
- Enable Features bit 1 Reverse enable on cruise.
- If in a speed limiting mode, limit the reverse speed via Vehicle jog speed.
- Enable Features bit 7 Reverse interlock disable if you wish to be able to switch to reverse without coming to a full stop first.
- Enable reverse and verify ebike flags bit 8 Reverse is active by pulling Cruise to ground. E.g. close the switch.
Firmware 6.019 and newer
- Enable Features bit 1 Reverse enable on cruise.
- Select the Reverse_Enable_Source (address 1936).
- If in a speed limiting mode, limit the reverse speed via Vehicle jog speed.
- Enable Features bit 7 Reverse interlock disable if you wish to be able to switch to reverse without coming to a full stop first.
- Enable reverse and verify ebike flags bit 8 Reverse is active.
- For Cruise or PFS, pull the input to ground. E.g. Close the switch.
- For network, a command to enable Remote Digital Commands bit 15 Enable reverse must be sent.
Configuration parameters
Name | Description | Units | Address |
212bit1 | |||
1936 | |||
496bit15 | |||
230 | |||
212bit7 |
Status verification parameters
Name | Description | Units | Address |
327bit5 |