Controller Temperature Foldback
This features is described for your reference only, its parameters are fixed and cannot be changed or modified.
Introduction
The controllers contain two integrated temperature sensors, one monitors the powerboard (MOSFETs) temperature, controller temperature, and the other monitors the digital signal processor temperature, dsp core temperature.
Controller temperature-based foldback references two parameters, Controller foldback starting temperature and Controller foldback end temperature.
Controller foldback starting temperature is the temperature at which the controller starts folding back the peak motor current limit.
Controller foldback ending temperature is the temperature at which the controller has folded back the peak motor current limit to zero amps
Reference Parameters
Controller temperature
Name | Description | Units | Address |
259 | |||
281 |
Controller temperature foldback
Name | Description | Units | Address |
35 | |||
36 | |||
321 | |||
323 |